<?xml version="1.0" encoding="utf-8" standalone="yes"?>
<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/">
  <channel>
    <title>Cement Science</title>
    <link>https://www.cementscience.com/</link>
    <description>Recent content on Cement Science</description>
    <generator>Hugo</generator>
    <language>en</language>
    <lastBuildDate>Sun, 26 Apr 2015 00:00:28 +0000</lastBuildDate>
    <atom:link href="https://www.cementscience.com/index.xml" rel="self" type="application/rss+xml" />
    <item>
      <title>Use Vaseline to cover the surface of alkali activated cement paste during setting test</title>
      <link>https://www.cementscience.com/2015/04/use-vaseline-to-cover-the-surface-of-alkali-activated-cement-paste-during-setting-test.html</link>
      <pubDate>Sun, 26 Apr 2015 00:00:28 +0000</pubDate>
      <guid>https://www.cementscience.com/2015/04/use-vaseline-to-cover-the-surface-of-alkali-activated-cement-paste-during-setting-test.html</guid>
      <description>&lt;p&gt;Setting of cement paste is an important property to be measured. So how to measure it? The most common method is using Vicat needle instrument. The European Standards and ASTM both document the detailed method. One of the deferences of the two methods lies on the treatment of the surface of sample.&lt;/p&gt;
&lt;p&gt;The &amp;ldquo;Methods of testing cement — Part 3: Determination of setting times and soundness&amp;rdquo; says &amp;ldquo;Place the filled mould and base-plate in the container, add water so that the surface of the paste is submerged to a depth of at least 5 mm, and store in the temperature controlled enclosure at (20,0 ± 1,0) °C&amp;rdquo;.&lt;/p&gt;</description>
      <content:encoded><![CDATA[<p>Setting of cement paste is an important property to be measured. So how to measure it? The most common method is using Vicat needle instrument. The European Standards and ASTM both document the detailed method. One of the deferences of the two methods lies on the treatment of the surface of sample.</p>
<p>The &ldquo;Methods of testing cement — Part 3: Determination of setting times and soundness&rdquo; says &ldquo;Place the filled mould and base-plate in the container, add water so that the surface of the paste is submerged to a depth of at least 5 mm, and store in the temperature controlled enclosure at (20,0 ± 1,0) °C&rdquo;.</p>
<p>While the ASTM &ldquo;C191 − 13 Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle&rdquo; shows that &ldquo;Immediately after molding, place the test specimen in the moist cabinet or moist room and allow it to remain there except when penetration measurements are being made.&rdquo;</p>
<p>We could see the point here is trying to keep the constant water to cement ratio of the surface of the sample, otherwise the dried surface would make trouble for the penetrating of the needle and give fake setting time point.</p>
<p>However, it is difficult to apply European Standards to measure the setting of alkali activated cement paste. As the alkali ions dissolve into the water and significantly change the chemistry of the surface layer. If there is no moist curing cabinet, how can we test the setting of alkali activated cement paste?</p>
<p><img alt="vaseline-cement" loading="lazy" src="/wp-content/uploads/2015/04/vaseline-cement.jpg"></p>
<p>Here we share the trick that we have been using at our lab with you. Use Vaseline (petroleum jelly)! After pouring the paste into the mould, cover the surface with a thin layer of melting Vaseline (about 100 °C), the Vaseline is then immediately cooled into a layer of gel.</p>
<p>Why choose Vaseline instead of water?</p>
<ul>
<li>The Vaseline is easy to be melted and cover the surface and soon returns to soft gel status.</li>
<li>The soft gel functions as the water layer preventing the surface losing water due to drying.</li>
<li>What is more, the Vaseline does not have chemical reaction with alkali activated cement, nor do the alkali ions dissolve into Vaseline.</li>
<li>And the price of Vaseline is cheap.</li>
</ul>
<p>So ladies use Vaseline for makeup, we use it for cement research.</p>
]]></content:encoded>
    </item>
    <item>
      <title>The method to measure the plastic viscosity of cement paste</title>
      <link>https://www.cementscience.com/2015/03/the-method-to-measure-the-plastic-viscosity-of-cement-paste.html</link>
      <pubDate>Sat, 07 Mar 2015 00:00:44 +0000</pubDate>
      <guid>https://www.cementscience.com/2015/03/the-method-to-measure-the-plastic-viscosity-of-cement-paste.html</guid>
      <description>&lt;p&gt;In the previous post, I introduced the &lt;a href=&#34;https://www.cementscience.com/2015/02/the-right-protocol-to-measure-yield-stress-of-cement-paste.html&#34;&gt;protocol to measure the yield stress&lt;/a&gt; of cement paste. I would like to share the method how to measure the plastic viscosity of cement paste.&lt;/p&gt;
&lt;p&gt;The principle determine the plastic viscosity of cement paste is using the relationship between shear rate and shear stress. Applying a serials of shear rate on the cement paste would result in the corresponding shear stress. After obtaining the set of shear rate and shear stress, the plastic viscosity of the paste is calculated by regression.&lt;/p&gt;</description>
      <content:encoded><![CDATA[<p>In the previous post, I introduced the <a href="https://www.cementscience.com/2015/02/the-right-protocol-to-measure-yield-stress-of-cement-paste.html">protocol to measure the yield stress</a> of cement paste. I would like to share the method how to measure the plastic viscosity of cement paste.</p>
<p>The principle determine the plastic viscosity of cement paste is using the relationship between shear rate and shear stress. Applying a serials of shear rate on the cement paste would result in the corresponding shear stress. After obtaining the set of shear rate and shear stress, the plastic viscosity of the paste is calculated by regression.</p>
<p><img alt="plastic-viscosity-cement-paste" loading="lazy" src="/wp-content/uploads/2016/01/plastic-viscosity-cement-paste.png"></p>
<p>The measured shear rate and shear stress of a cement paste, Measuring device: HAAKE™ VT550 (ViscoTester VT550), CR (Controlled shear Rate): 0-100 1/s; t 120.00 s; T 20.00 °C.</p>
<p>The paste should be measured by increasing shear rate and then the decreasing rate. Typical shear rate applied on cement paste is linearly between 0 and 100 1/s. Since the rheological feature of most of cement pastes is a kind of Bingham model, we can choose the liner part of the decreasing shear curve from the date set (shear rate vs. shear stress) for the regression. The slope from the regression equation is the so-called plastic viscosity.</p>
<p>However, if the rheological cure of the paste behaves rather than Bingham model, selecting an appropriate model is necessary.</p>
]]></content:encoded>
    </item>
    <item>
      <title>The right protocol to measure yield stress of cement paste</title>
      <link>https://www.cementscience.com/2015/02/the-right-protocol-to-measure-yield-stress-of-cement-paste.html</link>
      <pubDate>Fri, 06 Feb 2015 00:00:02 +0000</pubDate>
      <guid>https://www.cementscience.com/2015/02/the-right-protocol-to-measure-yield-stress-of-cement-paste.html</guid>
      <description>&lt;p&gt;The rheology of cementitious material paste is complex and difficult to be investigated. One value of rheology is yield stress. The best method to measure the yield stress in laboratory is using the vane method. However, there is no much literature reporting an practical and detailed testing protocol to measure the yield stress of cement paste. Here I briefly introduce the protocol I am using at our laboratory.&lt;/p&gt;
&lt;p&gt;To obtain stable and reliable results, we should choose the same container and the same mixing procedure. We normally use a plastic beaker with a volume 500 ml, for the beaker has enough diameter and depth for the test without the influence of boundary effect, i.e. the diameter is two times larger than the diameter of the vane. For each test, 270 g of cement is mixed with relevant water at the required water to cement ratio. For the mixing, a high-shear mixer is applied with a shear rate 800 RPM for 2 minutes.&lt;/p&gt;</description>
      <content:encoded><![CDATA[<p>The rheology of cementitious material paste is complex and difficult to be investigated. One value of rheology is yield stress. The best method to measure the yield stress in laboratory is using the vane method. However, there is no much literature reporting an practical and detailed testing protocol to measure the yield stress of cement paste. Here I briefly introduce the protocol I am using at our laboratory.</p>
<p>To obtain stable and reliable results, we should choose the same container and the same mixing procedure. We normally use a plastic beaker with a volume 500 ml, for the beaker has enough diameter and depth for the test without the influence of boundary effect, i.e. the diameter is two times larger than the diameter of the vane. For each test, 270 g of cement is mixed with relevant water at the required water to cement ratio. For the mixing, a high-shear mixer is applied with a shear rate 800 RPM for 2 minutes.</p>
<p>As soon as the well mixed paste is ready, let the blades of the vane of rheometer immerse in the paste. Make sure the top surface of the paste staying between the two lines labeled on the shaft.</p>
<p>The principle to measure the yield stress is applying a very low fixed shear rate on the paste, e.g 0.02-0.001 1/s, then the shear stress linearly increases till yield stress. As shown in the recorded data (Fig 1), the shear stress drops remarkably when the paste is yield, thus the maximum stress is the yield stress, i.e. dynamic yield stress.</p>
<p><img alt="rheology-yield-stress" loading="lazy" src="/wp-content/uploads/2016/01/rheology-yield-stress.png"></p>
<p>Fig. 1. Measuring device: HAAKE™ VT550 (ViscoTester VT550), CR (Controlled shear Rate): 0.01000 1/s; t 120.00 s; T 20.00 °C.</p>
<p>If the maximum stress does not occur within the testing period, longer time or higher shear rate may be tried. It is also worth to note that this method gives good result for paste with yield stress higher than 10 Pa.</p>
]]></content:encoded>
    </item>
    <item>
      <title>How to define particle size?</title>
      <link>https://www.cementscience.com/2015/01/how-to-define-particle-size.html</link>
      <pubDate>Fri, 23 Jan 2015 00:00:13 +0000</pubDate>
      <guid>https://www.cementscience.com/2015/01/how-to-define-particle-size.html</guid>
      <description>&lt;p&gt;Particle size is a very important property in the research field of cementitious materials, e.g. modeling, reaction kinetics.&lt;/p&gt;
&lt;p&gt;&lt;a href=&#34;http://www.atascientific.com.au/publications/wp-content/uploads/2012/07/MRK1806-01-basic-guide-to-particle-characterisation.pdf&#34;&gt;Particles are 3-dimensional objects&lt;/a&gt;, and unless they are perfect spheres, e.g. emulsions or bubbles, they cannot be fully described by a single dimension such as a radius or diameter.&lt;/p&gt;
&lt;p&gt;In order to simplify the measurement process, it is often convenient to define the particle size using the concept of equivalent spheres. In this case the particle size is defined by the diameter of an equivalent sphere having the same property as the actual particle such as volume or mass for example.&lt;/p&gt;</description>
      <content:encoded><![CDATA[<p>Particle size is a very important property in the research field of cementitious materials, e.g. modeling, reaction kinetics.</p>
<p><a href="http://www.atascientific.com.au/publications/wp-content/uploads/2012/07/MRK1806-01-basic-guide-to-particle-characterisation.pdf">Particles are 3-dimensional objects</a>, and unless they are perfect spheres, e.g. emulsions or bubbles, they cannot be fully described by a single dimension such as a radius or diameter.</p>
<p>In order to simplify the measurement process, it is often convenient to define the particle size using the concept of equivalent spheres. In this case the particle size is defined by the diameter of an equivalent sphere having the same property as the actual particle such as volume or mass for example.</p>
<p>It is important to realize that different measurement techniques use different equivalent sphere models and therefore will not necessarily give exactly the same result for the particle diameter.</p>
<p>Below is a schematic figure illustrating the definition of particle size based on different equivalent spheres.</p>
<p><img alt="particle-size" loading="lazy" src="/wp-content/uploads/2015/05/particle-size.jpg"></p>
<p>Definition of particle size</p>
]]></content:encoded>
    </item>
    <item>
      <title>What is Geopolymer cement?</title>
      <link>https://www.cementscience.com/2014/12/what-is-geopolymer-cement.html</link>
      <pubDate>Mon, 15 Dec 2014 00:00:49 +0000</pubDate>
      <guid>https://www.cementscience.com/2014/12/what-is-geopolymer-cement.html</guid>
      <description>&lt;p&gt;I have been confused by the term &amp;ldquo;Geopolymer cement (concrete)&amp;rdquo; for long time. Some researchers told me Geopolymer cement is essentially alkali activated cement/material (AAMs), such as alkali activated slag and fly ash. Since alkali activated slag is indeed a kind of geopolymer cement, it looks logical to consider Geopolymer cement as alkali activated cement.&lt;/p&gt;
&lt;p&gt;Is it correct? Recently, I read the State of the Art report on alkali activated cement (Alkali Activated Materials State-of-the-Art Report, RILEM TC 224-AAM), finding the description:&lt;/p&gt;</description>
      <content:encoded><![CDATA[<p>I have been confused by the term &ldquo;Geopolymer cement (concrete)&rdquo; for long time. Some researchers told me Geopolymer cement is essentially alkali activated cement/material (AAMs), such as alkali activated slag and fly ash. Since alkali activated slag is indeed a kind of geopolymer cement, it looks logical to consider Geopolymer cement as alkali activated cement.</p>
<p>Is it correct? Recently, I read the State of the Art report on alkali activated cement (Alkali Activated Materials State-of-the-Art Report, RILEM TC 224-AAM), finding the description:</p>
<blockquote>
<p>Low-calcium alkali-activated systems, predominantly dealing with alkali aluminosilicates and including those materials which are now widely known as ‘geopolymers’.</p>
</blockquote>
<p>It is clear that not all alkali activated cements are geopolymers. Just those with low calcium materials activated by alkali in cement industry are regarded as geopolymer cement, in other words, geopolymers are shown here as a subset of AAMs, with the highest Al and lowest Ca concentrations.</p>
<p>BTW, Davidovits is the first researcher applied the name ‘geopolymer’ to these low calcium materials activated by alkali. He was working in France, patented numerous aluminosilicate-based formulations for niche applications from the early 1980s onwards.</p>
]]></content:encoded>
    </item>
    <item>
      <title>Influence of Particle Size on the Early Hydration of Slag Particle Activated by Ca(OH)2 Solution</title>
      <link>https://www.cementscience.com/2014/02/influence-of-particle-size-on-the-early-hydration-of-slag-particle-activated-by-caoh2-solution.html</link>
      <pubDate>Thu, 20 Feb 2014 00:00:19 +0000</pubDate>
      <guid>https://www.cementscience.com/2014/02/influence-of-particle-size-on-the-early-hydration-of-slag-particle-activated-by-caoh2-solution.html</guid>
      <description>&lt;p&gt;Authors: Zhijun Tan, Geert De Schutter, Guang Ye, Yun Gao, Lieven Machiels&lt;/p&gt;
&lt;p&gt;Abstract:&lt;/p&gt;
&lt;p&gt;This paper investigates the influence of slag particle size on its hydration speed at particle level in the early age. Slags were separated with sieves into groups of different size fractions, considering a wide range of sizes. The chemical compositions of each group were analyzed by X-ray Fluorescence (XRF). Activated by 15% Ca(OH)&lt;!-- raw HTML omitted --&gt;2&lt;!-- raw HTML omitted --&gt; (by mass) at water/powder ratio 1:1, the hydration heat evolution was recorded by isothermal calorimetry up to 84 hours and converted to hydration degree. Based on the hydration degrees and particle size distributions, the rate of increase of hydrating layer thickness of each single slag particle (k value) was calculated. Results reveal that k values of coarse particles are higher than that of fine particles. Coarse particles contain higher content of CaO but relatively lower content of MgO, Al&lt;!-- raw HTML omitted --&gt;2&lt;!-- raw HTML omitted --&gt;O&lt;!-- raw HTML omitted --&gt;3&lt;!-- raw HTML omitted --&gt; and SiO&lt;!-- raw HTML omitted --&gt;2&lt;!-- raw HTML omitted --&gt;, resulting in higher reactivity index of (CaO+Al&lt;!-- raw HTML omitted --&gt;2&lt;!-- raw HTML omitted --&gt;O&lt;!-- raw HTML omitted --&gt;3&lt;!-- raw HTML omitted --&gt;+MgO)/SiO&lt;!-- raw HTML omitted --&gt;2&lt;!-- raw HTML omitted --&gt;.&lt;/p&gt;</description>
      <content:encoded><![CDATA[<p>Authors: Zhijun Tan, Geert De Schutter, Guang Ye, Yun Gao, Lieven Machiels</p>
<p>Abstract:</p>
<p>This paper investigates the influence of slag particle size on its hydration speed at particle level in the early age. Slags were separated with sieves into groups of different size fractions, considering a wide range of sizes. The chemical compositions of each group were analyzed by X-ray Fluorescence (XRF). Activated by 15% Ca(OH)<!-- raw HTML omitted -->2<!-- raw HTML omitted --> (by mass) at water/powder ratio 1:1, the hydration heat evolution was recorded by isothermal calorimetry up to 84 hours and converted to hydration degree. Based on the hydration degrees and particle size distributions, the rate of increase of hydrating layer thickness of each single slag particle (k value) was calculated. Results reveal that k values of coarse particles are higher than that of fine particles. Coarse particles contain higher content of CaO but relatively lower content of MgO, Al<!-- raw HTML omitted -->2<!-- raw HTML omitted -->O<!-- raw HTML omitted -->3<!-- raw HTML omitted --> and SiO<!-- raw HTML omitted -->2<!-- raw HTML omitted -->, resulting in higher reactivity index of (CaO+Al<!-- raw HTML omitted -->2<!-- raw HTML omitted -->O<!-- raw HTML omitted -->3<!-- raw HTML omitted -->+MgO)/SiO<!-- raw HTML omitted -->2<!-- raw HTML omitted -->.</p>
<p>Keywords: Blast-furnace slag, Particle size distribution, Reactivity, Hydration degree</p>
<p><a href="/ftp/Influence-of-particle-size-on-the-early-hydration-of-slag-particle-activated-by-Ca(OH)2-solution.pdf">Full paper link</a>.</p>
]]></content:encoded>
    </item>
    <item>
      <title>What can you do using cement? Funny stuff made of cement</title>
      <link>https://www.cementscience.com/2013/08/what-can-you-do-using-cement-funny-stuff-made-of-cement.html</link>
      <pubDate>Sat, 17 Aug 2013 14:35:48 +0000</pubDate>
      <guid>https://www.cementscience.com/2013/08/what-can-you-do-using-cement-funny-stuff-made-of-cement.html</guid>
      <description>&lt;p&gt;It is well known that cement is the most used construction material in the world. In the mind of most of people, cement is a kind of grey powder and only used as construction material, to build gardens, bridges, road etc. However, we can do more with cement, here are nice pictures showing some stuff made of cement. Creactive!&lt;/p&gt;
&lt;p&gt;Even as a guy like me who deals with cement everyday, I really think these items are pretty funny. What do you think you can do using cement? make the most of your imagination, dare to think.&lt;/p&gt;</description>
      <content:encoded><![CDATA[<p>It is well known that cement is the most used construction material in the world. In the mind of most of people, cement is a kind of grey powder and only used as construction material, to build gardens, bridges, road etc. However, we can do more with cement, here are nice pictures showing some stuff made of cement. Creactive!</p>
<p>Even as a guy like me who deals with cement everyday, I really think these items are pretty funny. What do you think you can do using cement? make the most of your imagination, dare to think.</p>
<p><img alt="cement-funny-stuff (1)" loading="lazy" src="/wp-content/uploads/2013/08/cement-funny-stuff-1.jpg"></p>
<p><img alt="cement-funny-stuff (17)" loading="lazy" src="/wp-content/uploads/2013/08/cement-funny-stuff-17.jpg"></p>
<p><img alt="cement-funny-stuff (18)" loading="lazy" src="/wp-content/uploads/2013/08/cement-funny-stuff-18.jpg"></p>
<p><img alt="cement-funny-stuff (19)" loading="lazy" src="/wp-content/uploads/2013/08/cement-funny-stuff-19.jpg"></p>
<p><img alt="cement-funny-stuff (20)" loading="lazy" src="/wp-content/uploads/2013/08/cement-funny-stuff-20.jpg"></p>
<p><img alt="cement-funny-stuff (21)" loading="lazy" src="/wp-content/uploads/2013/08/cement-funny-stuff-21.jpg"></p>
<p><img alt="cement-funny-stuff (22)" loading="lazy" src="/wp-content/uploads/2013/08/cement-funny-stuff-22.jpg"></p>
<p><img alt="cement-funny-stuff (23)" loading="lazy" src="/wp-content/uploads/2013/08/cement-funny-stuff-23.jpg"></p>
<p><img alt="cement-funny-stuff (24)" loading="lazy" src="/wp-content/uploads/2013/08/cement-funny-stuff-24.jpg"></p>
<p><img alt="cement-funny-stuff (25)" loading="lazy" src="/wp-content/uploads/2013/08/cement-funny-stuff-25.jpg"></p>
<p><img alt="cement-funny-stuff (26)" loading="lazy" src="/wp-content/uploads/2013/08/cement-funny-stuff-26.jpg"></p>
<p><img alt="cement-funny-stuff (27)" loading="lazy" src="/wp-content/uploads/2013/08/cement-funny-stuff-27.jpg"></p>
<p><img alt="cement-funny-stuff (28)" loading="lazy" src="/wp-content/uploads/2013/08/cement-funny-stuff-28.jpg"></p>
<p><img alt="cement-funny-stuff (29)" loading="lazy" src="/wp-content/uploads/2013/08/cement-funny-stuff-29.jpg"></p>
<p><img alt="cement-funny-stuff (30)" loading="lazy" src="/wp-content/uploads/2013/08/cement-funny-stuff-30.jpg"></p>
<p><img alt="cement-funny-stuff (31)" loading="lazy" src="/wp-content/uploads/2013/08/cement-funny-stuff-31.jpg"></p>
]]></content:encoded>
    </item>
    <item>
      <title>The Influence of Slag on the Hydration of Cement</title>
      <link>https://www.cementscience.com/2013/07/the-influence-of-slag-on-the-hydration-of-cement.html</link>
      <pubDate>Wed, 31 Jul 2013 18:29:45 +0000</pubDate>
      <guid>https://www.cementscience.com/2013/07/the-influence-of-slag-on-the-hydration-of-cement.html</guid>
      <description>&lt;p&gt;These following conclusions are summarized from the work of Kocaba&amp;rsquo;s PhD thesis.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;&lt;strong&gt;alite&lt;/strong&gt;: no influence is shown on the consumption of alite measured by XRD.&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;belite&lt;/strong&gt;: the substitution of cement by both slags seems to result in a delay in the hydration of belite in the first days.&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;aluminate phase&lt;/strong&gt;: there is a filler effect using inert filler at about 12 hours of hydration, which shows slag can also has filler effect in the early hydration period. Transformation of AFt to AFm causes cumulative heat shoulder at about 60 hours.&lt;/li&gt;
&lt;/ul&gt;
&lt;blockquote&gt;
&lt;p&gt;For all systems, slags did not have a strong influence on hydration of C3A phases. Taking into account the low content of C3A and the corresponding error, it was difficult to highlight any relevant difference between blended paste and corresponding pure pastes.&lt;/p&gt;
&lt;p&gt;There was no evidence of slag itself reacting and the effect of slag on aluminate phases can be only attributed to a filler effect.&lt;/p&gt;
&lt;p&gt;The raw calorimetry curves of pure cement system showed a peak (called IV) which was attributed to monosulfoaluminate reaction just around 60 hours of reaction. In this way, calcium hemicarboaluminate and monocarboaluminate could be some possible AFm phases corresponding to the second peak of aluminate. But there is no evidence of that and it could be some monosulfate. The corresponding XRD patterns did not show any peaks corresponding to AFm phases at early ages which indicate a very low content if they are present.&lt;/p&gt;
&lt;/blockquote&gt;</description>
      <content:encoded><![CDATA[<p>These following conclusions are summarized from the work of Kocaba&rsquo;s PhD thesis.</p>
<ul>
<li><strong>alite</strong>: no influence is shown on the consumption of alite measured by XRD.</li>
<li><strong>belite</strong>: the substitution of cement by both slags seems to result in a delay in the hydration of belite in the first days.</li>
<li><strong>aluminate phase</strong>: there is a filler effect using inert filler at about 12 hours of hydration, which shows slag can also has filler effect in the early hydration period. Transformation of AFt to AFm causes cumulative heat shoulder at about 60 hours.</li>
</ul>
<blockquote>
<p>For all systems, slags did not have a strong influence on hydration of C3A phases. Taking into account the low content of C3A and the corresponding error, it was difficult to highlight any relevant difference between blended paste and corresponding pure pastes.</p>
<p>There was no evidence of slag itself reacting and the effect of slag on aluminate phases can be only attributed to a filler effect.</p>
<p>The raw calorimetry curves of pure cement system showed a peak (called IV) which was attributed to monosulfoaluminate reaction just around 60 hours of reaction. In this way, calcium hemicarboaluminate and monocarboaluminate could be some possible AFm phases corresponding to the second peak of aluminate. But there is no evidence of that and it could be some monosulfate. The corresponding XRD patterns did not show any peaks corresponding to AFm phases at early ages which indicate a very low content if they are present.</p>
</blockquote>
<ul>
<li><strong>Ferite</strong>: The slags seem to favour the hydration of the ferrite phase.</li>
</ul>
<p><strong>Influence of slag on the degree of reaction of cement</strong></p>
<blockquote>
<p>From XRD-Rietveld refinement and SEM-IA, the degree of reaction of cement did not seem to be strongly affected by the slag.</p>
</blockquote>
]]></content:encoded>
    </item>
    <item>
      <title>The Importance of Cement and its Future</title>
      <link>https://www.cementscience.com/2013/06/the-importance-of-cement-and-its-future.html</link>
      <pubDate>Tue, 04 Jun 2013 00:00:35 +0000</pubDate>
      <guid>https://www.cementscience.com/2013/06/the-importance-of-cement-and-its-future.html</guid>
      <description>&lt;p&gt;Concrete is the most used material in the world because of its cheap price and large quantity. It is needless to say concrete is made of cement. However, cement is also a criticized material by the public, for its intensive CO&lt;!-- raw HTML omitted --&gt;2&lt;!-- raw HTML omitted --&gt; emission from production process. The production of cement accounts for about 5-8% of the non-natural CO&lt;!-- raw HTML omitted --&gt;2&lt;!-- raw HTML omitted --&gt; worldwide.&lt;/p&gt;</description>
      <content:encoded><![CDATA[<p>Concrete is the most used material in the world because of its cheap price and large quantity. It is needless to say concrete is made of cement. However, cement is also a criticized material by the public, for its intensive CO<!-- raw HTML omitted -->2<!-- raw HTML omitted --> emission from production process. The production of cement accounts for about 5-8% of the non-natural CO<!-- raw HTML omitted -->2<!-- raw HTML omitted --> worldwide.</p>
<p><img alt="Importance of Cement" loading="lazy" src="/wp-content/uploads/2013/06/concrete.png"></p>
<p><img alt="Importance of Cement" loading="lazy" src="/wp-content/uploads/2013/06/limestone_heat.png"></p>
<p><img alt="Importance of Cement" loading="lazy" src="/wp-content/uploads/2013/06/cement-plant.jpg"></p>
<p>People may ask, can we find an alternative construction material instead of cement? such as wood, steel. The annual usage of wood is much above the replanting level, and it is not possible to get wood in some places such as Africa and China. As for steel, it is costly and again the production of steel also gives CO<!-- raw HTML omitted -->2<!-- raw HTML omitted --> emission. Furthermore, the production of cement is not that energy intensive compared with other materials.</p>
<p><img alt="Importance of Cement" loading="lazy" src="/wp-content/uploads/2013/06/energy.png"></p>
<p>Actually, it is not possible to find an alternative construction material. 98% of the earth’s crust is made of eight elements: O, Si, Al, Fe, Ca, Na, K, Mg, which are the main elements of cement as well. From the long term run, the world will still need a large amount of cement. The demand of cement mainly comes from developing countries, such as India and China because of the urbanization and its population growth.</p>
<p><img alt="Importance of Cement" loading="lazy" src="/wp-content/uploads/2013/06/earth-crust.png"></p>
<p><img alt="Importance of Cement" loading="lazy" src="/wp-content/uploads/2012/07/construction-china.jpg"></p>
<p><img alt="Importance of Cement" loading="lazy" src="/wp-content/uploads/2013/06/cement-demand.png"></p>
<p>Since we have to use cement in the future, how can we do to reduce the CO<!-- raw HTML omitted -->2<!-- raw HTML omitted --> emission and what is the future of cement? Efforts have been doing ever since decades ago in the cement industry and research community.</p>
<p>On the one hand, cement plants nowadays burn (hazardous) waste, say, car tyres, as fuel to make cement. The wood floating on the water of Three Gorges Dam is even collected to make fuel for cement plants. On the other hand, the production process of cement has always been optimizing. Some cement plants can even reach 80% efficiency, which is a great achievement even from a theoretical standpoint.</p>
<p><img alt="Importance of Cement" loading="lazy" src="/wp-content/uploads/2013/06/car-tyre.png"></p>
<p><img alt="Importance of Cement" loading="lazy" src="/wp-content/uploads/2013/06/three-gorges-dam-wood.png"></p>
<p>Researchers of cement try to use less cement clinkers. One viable method is Supplementary Cementitious Materials (SCMs). SCMs are commonly industry by-products or raw materials, such as Slag, limestone, Fly ash, silica fume, natural pozzolan. Whether binary blended or even ternary blended, SCMs can replace part of cement without sacrificing equivalent engineering properties.</p>
<p><img alt="Importance of Cement" loading="lazy" src="/wp-content/uploads/2013/06/scm.png"></p>
<p>Considering the limited quantity and access of SCMs, SCMs are not a permanent sustainable way from a long term run. Some researchers are trying to utilize the unlimited amount of calcined clay, for the kaolinite content of clay has similar cementitious property. Work done replacing 30% of cement by calcined clay in Cuba shows the potential future of clay if well used.</p>
<p><img alt="Importance of Cement" loading="lazy" src="/wp-content/uploads/2013/06/clay.png"></p>
<p>Generally speaking, cement is a significantly important construction material, and it is not necessary to worry that much as for the CO<!-- raw HTML omitted -->2<!-- raw HTML omitted --> emission in the future.</p>
]]></content:encoded>
    </item>
    <item>
      <title>Buoyancy Effect of TGA Experiment</title>
      <link>https://www.cementscience.com/2013/04/buoyancy-effect-of-tga-experiment.html</link>
      <pubDate>Tue, 30 Apr 2013 16:53:27 +0000</pubDate>
      <guid>https://www.cementscience.com/2013/04/buoyancy-effect-of-tga-experiment.html</guid>
      <description>&lt;p&gt;&lt;strong&gt;What is Buoyancy Effect of TGA experiment?&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;TGA (thermogravimetric analysis) is an important method to analyze the hydration products of cementitious materials. When a TGA test for cementitious materials sample is performed, the initial TGA curve may appears as such:&lt;/p&gt;
&lt;p&gt;&lt;img alt=&#34;A typical TGA test result. Portland cement past, w/c=0.4, cured 1 day. &#34; loading=&#34;lazy&#34; src=&#34;https://www.cementscience.com/wp-content/uploads/2013/04/PC1D.jpg&#34;&gt;&lt;/p&gt;
&lt;p&gt;A typical TGA test result shows the buoyancy effect. Portland cement past, w/c=0.4, cured 1 day.&lt;/p&gt;
&lt;p&gt;As can be seen from the curve, the mass exceeded the original mass, which is not reasonable, since the decomposition of the sample always decrease the mass of testing sample. So why does this happen? This is because of the buoyancy effect in the TGA equipment.&lt;/p&gt;</description>
      <content:encoded><![CDATA[<p><strong>What is Buoyancy Effect of TGA experiment?</strong></p>
<p>TGA (thermogravimetric analysis) is an important method to analyze the hydration products of cementitious materials. When a TGA test for cementitious materials sample is performed, the initial TGA curve may appears as such:</p>
<p><img alt="A typical TGA test result. Portland cement past, w/c=0.4, cured 1 day. " loading="lazy" src="/wp-content/uploads/2013/04/PC1D.jpg"></p>
<p>A typical TGA test result shows the buoyancy effect. Portland cement past, w/c=0.4, cured 1 day.</p>
<p>As can be seen from the curve, the mass exceeded the original mass, which is not reasonable, since the decomposition of the sample always decrease the mass of testing sample. So why does this happen? This is because of the buoyancy effect in the TGA equipment.</p>
<p>Every substance found in a gas atmosphere is subjected to a buoyant force. This results in &ldquo;apparent&rdquo; mass changes. The degree of buoyancy, and thus the degree of mass change as well, are basically dependent on the volume of the substance and the density of the prevailing gas.</p>
<p>However, for thermogravimetric investigations, it is not the absolute value of the buoyancy at a certain temperature that is decisive, but rather its change as a function of temperature. A typical buoyancy curve is shown as follows.</p>
<p><img alt="TGA test" loading="lazy" src="/wp-content/uploads/2013/04/correction.jpg"></p>
<p>A blank TGA test.</p>
<p>It was recorded using a NETZSCH STA 409 with a DSC sample carrier in a static N2 atmosphere. There is no sample in the crucible, but the recorded result shows the mass is always over ZERO.</p>
<p>Due to the volume-dependence of the buoyancy, it is important to specify the sample carrier type in addition to the gas atmosphere, since different sample carrier/crucible combinations give rise to different &ldquo;apparent&rdquo; mass changes.</p>
<p><strong>How to remove the Buoyancy Effect?</strong></p>
<p>Knowing this, we can remove the buoyancy effect by running a blank test. Repeat the test with the same crucible but without anything in it or with inert material, then the buoyancy effect is recorded. Subtracting the buoyancy result from the first measurement result, the true mass change of the test is obtained.</p>
<p><img alt="A typical TGA test result after the subtracted the blank test, removing the buoyancy effect. Portland cement past, w/c=0.4, cured 1 day." loading="lazy" src="/wp-content/uploads/2013/04/PC1D2.jpg"></p>
<p>A typical TGA test result after the subtracted the blank test, removing the buoyancy effect. Portland cement past, w/c=0.4, cured 1 day.</p>
<p><strong>Why does the buoyancy curve initially show such a drastic rise?</strong></p>
<p>You may find the buoyancy curve initially shows a drastic rise, why is that? This phenomenon arises from the design of TGA device.</p>
<p>At low temperatures, heat transfer from the furnace to the sample thermocouple is exclusively through convection. Since a certain amount of time is required before the crucible material is evenly heated and the warm air preferably flows along the inside of the protective tube, and thus does not reach the crucible immediately, the actual temperature of the gas atmosphere is far higher, particularly at the beginning of a measurement, than the temperature sensor indicates. Therefore, the gas density changes dramatically in the beginning of the test, thus subjects dramatic “apparent mass” change.</p>
<p><img alt="A schematic figure showing the temperature difference" loading="lazy" src="/wp-content/uploads/2013/04/TGA.jpg"></p>
<p>A schematic figure showing the temperature difference.</p>