Use Vaseline to cover the surface of alkali activated cement paste during setting test
Setting of cement paste is an important property to be measured. So how to measure it? The most common method is using Vicat needle instrument. The European Standards and ASTM both document the detailed method. One of the deferences of the two methods lies on the treatment of the surface of sample. The “Methods of testing cement — Part 3: Determination of setting times and soundness” says “Place the filled mould and base-plate in the container, add water so that the surface of the paste is submerged to a depth of at least 5 mm, and store in the temperature controlled enclosure at (20,0 ± 1,0) °C”. ...